Apex Plaza

Cat A Office Fit out Design and Build

Full MEP isolations and removal within the ground floor Block A Building. 

Installation of new mains containment incorporated into a main MEP bulkhead to allow for ductwork and Air conditioning pipework to be installed in a set space.

New Mitsubishi AC System installed along with a AE200-E Controller interlinked to the current building wide BMS

Crane lift for mechanical plant onto the roof was carried out taking consideration of the adjacent train overhead lines.

New primary ductwork installed to supply fresh air to the AC units all insulated with an aluminium wrap.

Mains containment feeding any services was installed with galvanised conduit for the lighting control, lighting and high level Power.

Lighting control system Simmtronic utilising day light dimming and emergency testing 

New suspended LED luminaires were installed via a gripple suspension system and local Flex 7 connections

Value -  £245,000

Bias - MEP